H05V-R / H07V-R Flexible Stranded Copper PVC Insulated Single Core Electrical Cable Wire

H05V-R / H07V-R Flexible Stranded Copper PVC Insulated Single Core Electrical Cable Wire image
Get Latest Price Request a quote
You May Like
Product Details
Packaging & Delivery
Product Description
Scope of application
System
This product is suitable for AC 50Hz, transmission of electrical energy in a power line whose voltage does not exceed 450/750V power.
Occasion
Power plants, fixed wiring, household appliances, meters, lighting and telecommunication equipment with AC voltage of 450/750V and below
Product characteristics
Insulation performance is good, have a certain acid and alkali resistance, oil resistance, moisture-proof characteristics; Stable structure, process of simple manufacturing, low price
Compliant standard
Executive standard
GB/T 5023-2008 PVC insulated cable,wires and flexible wires with rated voltage of 450/750V and below
Additional standard
Service characteristics
Rated voltage
0.45/0.75kV
Operating temperature
Cable conductor allows the highest working temperature 70 ºC for a long time.
Ambient temperature
The ambient temperature of the cable should not be lower than 0 ° C.
Laying temperature
The laying temperature of the cable should not be lower than 0ºC.
Bending radius
The allowable bending radius of cable with outer diameter (D) less than 25mm shall not be less than 4D. The allowable bending radius of cable with outer diameter (D) of 25mm and above shall not be less than 6D.
Identification of product
Wire core
Blue
Rind
Cables shall be continuously identified with the manufacturer’s name, product model and rated voltage, The logo of factory‘s name can be a duplicate of the manufacturer or repetitive identification.
The distance between the end of one complete sign and the beginning of the next sign shall not exceed 275mm; The printed mark should be erasure resistant and not easy to fall off, and the printed content on the surface should be clear and recognizable
Rated Voltage | No.of CORES | specification | conductor structure | outer diameter of conductor(mm) | insulation thickness(mm) | reference outer diameter(mm) | reference weight(mm) | DC RESISTANCE (OHM/KM) | Minimum insulation resistance at operating temperature(OHM-KM) | Test voltage(KV/min) | Maximum allowable pulling force of conductor(N) |
450/750V | 1 | 1.5 | 1/1.38 | 1.38 | 0.7 | 2.9 | 20.9 | 12.1 | 0.011 | 2.5/5 | 105 |
1 | 2.5 | 1/1.78 | 1.78 | 0.8 | 3.5 | 32.8 | 7.41 | 0.01 | 2.5/5 | 175 | |
1 | 4 | 1/2.25 | 2.25 | 0.8 | 4 | 47.9 | 4.61 | 0.0085 | 2.5/5 | 280 | |
1 | 6 | 1/2.76 | 2.76 | 0.8 | 4.5 | 67.8 | 3.08 | 0.007 | 2.5/5 | 420 | |
1 | 10 | 7/1.35 | 4.05 | 1 | 6.3 | 116.3 | 1.83 | 0.0065 | 2.5/5 | 700 | |
1 | 16 | 7/1.66 | 4.98 | 1 | 7.1 | 167.1 | 1.15 | 0.005 | 2.5/5 | 1120 | |
1 | 25 | 7/2.14 | 6.42 | 1.2 | 9.1 | 268.8 | 0.727 | 0.005 | 2.5/5 | 1750 | |
1 | 35 | 7/2.52 | 7.56 | 1.2 | 10.2 | 364.6 | 0.524 | 0.0043 | 2.5/5 | 2450 | |
1 | 50 | 19/1.78 | 8.9 | 1.4 | 12 | 517.7 | 0.387 | 0.0043 | 2.5/5 | 3500 | |
1 | 70 | 19/2.14 | 10.7 | 1.4 | 13.8 | 708.2 | 0.268 | 0.0035 | 2.5/5 | 4900 | |
1 | 95 | 19/2.52 | 12.6 | 1.6 | 16.1 | 959.7 | 0.193 | 0.0035 | 2.5/5 | 6650 | |
1 | 120 | 37/2.03 | 14.21 | 1.6 | 17.7 | 1194.8 | 0.153 | 0.0032 | 2.5/5 | 8400 | |
1 | 150 | 37/2.25 | 15.75 | 1.8 | 19.7 | 1493.4 | 0.124 | 0.0032 | 2.5/5 | 10500 | |
1 | 185 | 37/2.52 | 17.64 | 2 | 22 | 1843.5 | 0.0991 | 0.0032 | 2.5/5 | 12950 | |
1 | 240 | 61/2.25 | 20.25 | 2.2 | 25.1 | 2383.5 | 0.0754 | 0.0032 | 2.5/5 | 16800 | |
1 | 300 | 61/2.52 | 22.68 | 2.4 | 28 | 2971.5 | 0.0601 | 0.003 | 2.5/5 | 21000 | |
1 | 400 | 61/2.85 | 25.65 | 2.6 | 31.4 | 3927.4 | 0.047 | 0.0028 | 2.5/5 | 28000 |
Packaging
Cable in rolls or coils is orderly winding and properly packed
The reel of cable shall comply with JB/T8137-1999,The end of cable should be reliably sealed, The cable ends extending out of the reel should be protected by a protective cover, and the length of extension should be less than 300mm.
The package of cable should be attached with a label indicating: manufacturer name, model, specification, rated voltage, length, quality, manufacturing date, standard number or certification mark, correct rotation direction of the cable drum, etc.
transportation
Transportation generally takes the form of vehicles or ships. During transportation, the cables must be firmly fixed to avoid damage to the cables or disks due to collision or overturning.
storage
Finished cables should be stored in an environment with a temperature between 5 and 40 degrees Celsius and a humidity below 85%. They should not be exposed to direct sunlight or rain. They should be properly ventilated to keep the environment dry.
Ordering matters
Necessary information of ordering such as cable model, specification, length, packaging method, date of delivery, etc. should be correctly indicated.
For example
Model of cable:BVR
specification:7×1.0
length:1000m
packaging method:Pure and wooden tray
date of delivery:Validity period days
transportation method:transport of train,transport of car,transport of ship,transport of airplane
trading locations:warehouse of demander,construction site,pick up by the demander
We are China H05V-R / H07V-R Flexible Stranded Copper PVC Insulated Single Core Electrical Cable Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: Henan Guowang Cable Group Co., Ltd., PVC Insulated, Round Wire