Product Description
Application
- When used as type THHN/THWN-2, conductors are suitable for use in wet or dry locations at temperatures not to exceed 90°C both dry and wet locations or not to exceed 75°C exposed to oil and gasoline.
- For 50mm²-500mm², Cable tray (CT) rated THHN/THWN-2 can be installed in Cable Trays
Specification
- The THHN/THWN-2 conductors are designed according to local and internationally recognized and accepted standards: ASTM: B3, B8
- ASTM: B3, B8
- Underwriters Laboratory: Listed under file #E-55448 for AWG Conductor sizes
- PNS: 35, 260, and 1207 Specification
- PEC 2009 Article 3.18 compliant for Cable tray
- NEC Article 318 compliant for Cable tray
Features
- Designed to operate at a maximum conductor temperature of 90°C both for wet and dry locations
- Higher cable ampacity
- Available in six standard colors (red, black, white, green, yellow, and blue)
- Jacketed with nylon for mechanical protection; greater resistance against abrasion, resistance to petroleum by-products, chemical agents and oils, and termite resistant.
- With sequential cable marker printed on the cable surface for sizes 38mm² up to 500mm² to indicate the length of the cable, act as cable usage reference and for inventory control
- Residential Homes
- Residential & Commercial Buildings (Mixed Use)
- Industrial/Manufacturing Buildings/Facilities
- Power Utliities
- Distributions/Transmissions
- Power Generation/Industrial Plants/Renewables
- Telcoms Distribution
- Data Centers
- Cell Sites
- Special Buildings such as infra projects (airports/LRT-Train/Subways)
COPPER BUILDING WIRE TYPE THHN/THWN – 2
Copper 600V 90°C Dry or Wet PVC Insulated and Polyamide (Nylon) Jacketed, Single Core
Sizes | Equivalent sizes | Conductor diameter | Cable Diameter | Cable weight | Cable ampacity | Packaging scheme |
mm | mm | kg/km | A** | m | ||
1.6mm solid | 14 awg | 1.6 | 2.6 | 22 | 25+ | 150m |
2.0mm solid | 12 awg | 2.0 | 3.0 | 33 | 30+ | 150m |
2.6mm solid | 10 awg | 2.6 | 3.8 | 55 | 40+ | 150m |
3.2mm solid | 8 awg | 3.2 | 5.1 | 88 | 55+ | 150m |
2.0mm2 strands | 14 awg | 1.8 | 2.8 | 24 | 25+ | 150m |
3.5mm2 strands | 12 awg | 2.3 | 3.3 | 37 | 30+ | 150m |
5.5mm2 strands | 10 awg | 2.9 | 4.1 | 58 | 40+ | 150m |
8.0mm2 strands | 8 awg | 3.6 | 5.5 | 96 | 55 | 150m |
14mm2 strands | 6 awg | 4.6 | 6.5 | 147 | 70 | 150m |
22mm2 strands | 4 awg | 5.7 | 8.1 | 232 | 90 | 150m |
30mm2 strands | 2 awg | 6.7 | 9.0 | 311 | 115 | 150m |
38mm2 strands | 1 awg | 7.8 | 10.8 | 414 | 130 | 300m |
50mm2 strands | 1/0 awg | 8.8 | 11.8 | 514 | 150 | 300m |
60mm2 strands | 2/0 awg | 9.8 | 12.7 | 625 | 170 | 300m |
80mm2 strands | 3/0 awg | 11.2 | 14.2 | 813 | 205 | 300m |
100mm2 strands | 4/0 awg | 12.7 | 15.7 | 1026 | 225 | 300m |
125mm2 strands | 250 mcm | 14.3 | 17.8 | 1298 | 265 | 300m |
150mm2 strands | 300 mcm | 15.7 | 19.3 | 1556 | 295 | 300m |
175mm2 strands | 350 mcm | 17.0 | 20.8 | 1741 | 325 | 300m |
200mm2 strands | 400 mcm | 17.8 | 21.4 | 1967 | 355 | 300m |
250mm2 strands | 500 mcm | 20.2 | 23.8 | 2519 | 400 | 300m |
300mm2 strands | 600 mcm | 22.3 | 26.3 | 2964 | 447 | 300m |
325mm2 strands | 650 mcm | 22.9 | 26.9 | 3218 | 470 | 300m |
375mm2 strands | 750 mcm | 25.0 | 29.6 | 3677 | 500 | 300m |
400mm2 strands | 800 mcm | 25.5 | 29.7 | 3974 | 515 | 300m |
500mm2 strands | 1000 mcm | 28.2 | 32.2 | 4809 | 580 | 300m |
*Unless otherwise specifically permitted, the overcurrent protection shall both exceed 15A for 2.0mm2 (1.6mm); 20A for 3.5mm2 (2.0mm) and 25A for 5.5mm2 as per PEC.
**Ampacity is based on 90°C not more than three current carrying conductors in conduit based on ambient temperature of 30°C as per PEC 2000.
***Effective impedance for three conductors in conduit 60Hz, 75°C and 600 Volts at P.F. multiplying current by effective impedance gives a good approximation for line to
neutral voltage drop.
+Diagrams of cables are illustrative only and not necessarily to scale. PDP reserves the right to change or vary the construction of any of their products without notice.
While every care has been taken in the preparation of this data sheet, PDP accept no liability of any kind and are not responsible for the results of any actions taken on
the basis of this information or resulting from errors or omissions. This technical data sheet is intended as a guide only; any person using it must make reference to
the appropriate local standards or authorities.
We are China 12AWG Copper Electrical Wire 3.5mm2 Stranded Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: 12AWG Copper Electrical Wire, 3.5mm2 Stranded Wire