600/1000V 10mm Airdac PVC Insulated Copper Concentric Cables Service Cables
                         600/1000V 10mm Airdac PVC Insulated Copper Concentric Cables Service Cables image
Get Latest Price Request a quote
You May Like
Product Details
Product Description
600/1000V 10mm Airdac PVC Insulated Copper Concentric Cable Service Cables
  Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017
  
   
  
  Conductor: Hard Drawn Copper Conductor – Class 2
  
  Insulation: LV-XLPE
  
  Phase Color Code(SNE): Red, Black & Bare Copper
  
  Phase Color Code (CNE): Red & Bare Copper
  
  Application: Used for house connections , with or without coms wire.
  
   Technical Data
  
  4mm², AIRDAC II CNE Cable
| Electrical Properties Cable size: 4mm² Phase Conductor Resistance (Ohm/km) DC @ 20 °C: 4,80 Phase Core Impedance (Z) (Ohm/km): 5,88 Current Rating (A)*: 30 Symmetrical Short Circuit Rating for 1s in kA: 0,572 * Note: – In air, with 30 °C ambient with maximum conductor temperature 90 °C Mechanical Properties Cable size: 4mm² Phase Conductor (No.xOD): 7×0.92mm Nominal Insulation Thickness: 1.0mm Earth size: 4mm² Earth Conductor (No.xOD): 8×0.85mm Nominal Sheath Thickness: 1.4mm Approximate Cable OD: 9.0mm Approximate Cable Mass: 121 kg/km Installation Data (SAG* mm): Span 10(mm) :40 Span 20(mm) :165 Span 30(mm) :370 Span 40(mm) :650 Span 50(mm) :1020 Based on UTS** :1480 MWT*** :370  | 
 
  
  10mm², AIRDAC II CNE Cable
| Electrical Properties Cable size: 10mm² Phase Conductor Resistance (Ohm/km) DC @ 20 °C: 1,90 Phase Core Impedance (Z) (Ohm/km): 2,34 Current Rating (A)*: 50 Symmetrical Short Circuit Rating for 1s in kA: 1,431 * Note: – In air, with 30 °C ambient with maximum conductor temperature 90 °C Mechanical Properties Cable size: 10mm² Phase Conductor (No.xOD): 7×1.45mm Nominal Insulation Thickness: 1.0mm Earth size: 10mm² Earth Conductor (No.xOD): 18×0.85mm Nominal Sheath Thickness: 1.4mm Approximate Cable OD: 11.0mm Approximate Cable Mass: 249 kg/km Installation Data (SAG* mm): Span 10(mm) :35 Span 20(mm) :140 Span 30(mm) :310 Span 40(mm) :550 Span 50(mm) :870 Based on UTS** :3600 MWT*** :900  | 
Separate Neutral and Earth (SNE) Airdac 600/1000V
| Cable Size  | 
Neutral Size  | 
Earth Size  | 
Pilot Cores  | 
Overall Diameter  | 
Cable Mass  | 
Current Rating  | 
Phase Core Impedance  | 
| mm² | mm² | mm² | mm | mm | kg/m | amps | ohms/km | 
| 10 | 10 | 7.5 | 2 x 0.5 | 12.8 | 0.32 | 90 | 2.34 | 
| 16 | 16 | 10 | 2 x 0.5 | 14.5 | 0.485 | 125 | 1.47 | 
Combined Neutral and Earth (CNE) Airdac 600/1000V
| Cable Size  | 
Earth Size  | 
Overall Diameter  | 
Cable Mass  | 
Current Rating  | 
Phase Core Impedance  | 
| mm² | mm² | mm | kg/m | amps | ohms/km | 
| 4 | 4 | 8.7 | 0.121 | 47 | 5.88 | 
| 10 | 10 | 11 | 0.249 | 86 | 2.34 | 
We are China 600/1000V 10mm Airdac PVC Insulated Copper Concentric Cables Service Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Tags: 4mm2 10mm2 Cne Airdac Cable, Airdac Cne Cable
				
					
                                    
                                    
                                    
                                    
                                    
                                    
                                    